Electric Vehicle Charging Wrie

当前位置:首页>Products>Electric Vehicle Charging Wrie

Charging cables for electric vehicles(DC)

上架时间:2023-08-25
浏览次数:354
产品详情

Product construction    

Conductor:Bare copper
Insulation:XLPE,TPE
Filler:PP rope
Tape:Non-woven
Sheath:TPE,TPU

    

Features    

Rating temperature:-40℃~90℃/105℃/125℃;   
Rated voltage:DC   1000V;
Compatibility test: According to  IEC   62893 or GB/T 33594;
Weather/UV Resistance test:  IEC   62893 or GB/T 33594;
Impact test: According to IEC 62893 or GB/T 33594;
Crush test: According to  IEC 62893   or GB/T 33594;
Bengding test: According to IEC 62893 or GB/T 33594;
Scrape abrasion test: According to    IEC 62893 or GB/T 33594;
Flame test: According to IEC 60332-1-2;
Resistance against chemicals: According to    IEC 62893 or GB/T 33594;
Min.bending radius:6D;
Environmental requirement:RoHS & REACH;
Reference standard:GB/T   33594、UL 62、UL 2263、EN 50620、TUV   2 PFG 1908、DEKRA-175、IEC 62893    


PARAMETER

产品系列
Product classification
电缆规格
Specification mm2
参考外径
   Nom.Dia. mm  
导体最大电阻
mΩ/m at.20℃
载流量
Ref.A
EV直流充电电缆2X2.5+1×2.5+2×0.75+(2×0.5)P+1×0.5+4×0.518.57.9820
2X2.5+1×2.5+2×0.75+(2×0.5)P+2×0.5+4×0.518.57.9820
2X4+1×4+2×0.75+(2×0.5)P+1×0.518.54.9530
2X4+1×4+2×0.75+(2×0.5)P+1×0.5+4×0.520.44.9530
2X4+1×4+2×0.75+(2×0.5)P+1×0.5+8×0.520.44.9530
2X6+1×6+2×1.5+(2×0.5)P+8×0.522.03.3038
2X10+1×10+2×2.5+(2×0.5)P+2×0.5+8×0.524.51.9154
2X16+1×16+2×2.5+(2×0.5)P+2×0.5+8×0.526.01.2171
2X16+1×10+2×4+2P(2×0.75)+P(6~8×0.75)28.01.2182
2X16+1×10+2×6+2P(2×0.75)+P(6~8×0.75)30.01.2182
2X16+1×10+2×4+2P(2×1)+P(6~8×1)28.01.2182
2X16+1×10+2×6+2P(2×1)+P(6~8×1)30.01.2182
2X25+1×25+2×4+2P(2×0.75)+P(6~8×0.75)32.00.78100
2X25+1×25+2×6+2P(2×0.75)+P(6~8×0.75)35.00.78100
2X25+1×25+2×4+2P(2×1)+P(6~8×1)32.00.78100
2X25+1×25+2×6+2P(2×1)+P(6~8×1)35.00.78100
2X35+1×25+2×4+2P(2×0.75)+P(6~8×0.75)36.00.554125
2X35+1×25+2×6+2P(2×0.75)+P(6~8×0.75)36.50.554125
2X35+1×25+2×4+2P(2×1)+P(6~8×1)36.00.554125
2X35+1×25+2×6+2P(2×1)+P(6~8×1)36.50.554125
2X50+1×25+2×4+2P(2×0.75)+P(6~8×0.75)37.00.386200
2X50+1×25+2×6+2P(2×0.75)+P(6~8×0.75)38.00.386200
2X50+1×25+2×4+2P(2×1)+P(6~8×1)37.00.386200
2X50+1×25+2×6+2P(2×1)+P(6~8×1)38.00.386200
2X70+1×25+2×4+2P(2×0.75)+P(6~8×0.75)40.00.272250
2X70+1×25+2×6+2P(2×0.75)+P(6~8×0.75)41.00.272250
2X70+1×25+2×4+2P(2×1)+P(6~8×1)40.00.272250
2X70+1×25+2×6+2P(2×1)+P(6~8×1)41.00.272250
2X80+1×25+2×4+2P(2×0.75)+P(6~8×0.75)42.00.243300
2X80+1×25+2×6+2P(2×0.75)+P(6~8×0.75)43.00.243300
2X80+1×25+2×4+2P(2×1)+P(6~8×1)42.00.243300
2X80+1×25+2×6+2P(2×1)+P(6~8×1)43.00.243300


Cable service environment

The warehous where cables are stored must not contain harmful gases that damage the insulation/sheath and corrode metals.During normal use,it is strictly fobidden to come into contact with acids,alkalis and mineral oils,and avoid using them in the open or exposed environment and under temperature conditions that do not meet the requirements of  the wire and cable standards.


Notes:The specifications,dimensions,and structure of the above products may be changed due to technological progress.Similar specifications can be designed and manufactured according to customer needs.

上一篇:Charging cables for electric vehicles(AC)

下一篇:没有了!

Scroll Top