Product construction
Conductor:Tinned copper
Insulation:PP(GN,WH)
Sheath:TPE-S
Features
Rating temperature:-40℃~125℃
Rated voltage:DC 60V;
Min.bending radius:
Single 3D
Multipe(<100X) 10D
Environmental requirement:RoHS & REACH;
Reference standard:IEC 19642
Radio frequency characteristics at 20℃
特性阻抗 Characteristic impedance | 100±10 Ω | ||||
频率 Frequency MHz | 1 | 20 | 66 | ||
回波损耗 Return loss ≥ dB | 20 | 20 | 14.8 | ||
频率 Frequency MHz | 1 | 10 | 33 | 66 | |
衰减 Insertion loss ≤ dB/m | 0.06 | 0.16 | 0.31 | 0.45 | |
频率 Frequency MHz | 1 | 50 | 200 | ||
LCTL ≥ dB | 46 | 46 | 34 | ||
TCL ≥ dB | 46 | 46 | 34 | ||
产品系列 | 电缆规格 mm2 | 参考外径 mm OD | 导体最大电阻 mΩ/m at.20℃ | 颜色 Color | |
FE-TPE | 2×0.35 | 3.8 | 55.5 | 黑色 BK |
Cable service environment
The warehous where cables are stored must not contain harmful gases that damage the insulation/sheath and corrode metals.During normal use,it is strictly fobidden to come into contact with acids,alkalis and mineral oils,and avoid using them in the open or exposed environment and under temperature conditions that do not meet the requirements of the wire and cable standards.
Notes:The specifications,dimensions,and structure of the above products may be changed due to technological progress.Similar specifications can be designed and manufactured according to customer needs.