PRODUCT DESCRIPTION
Rated temperature :80℃
Rated voltage :30V
Reference standard:UL Subject 758, UL1581 & CSA C22.2 No.210.2
Conductor: stranded tinned copper
Insulation: PVC
Passes UL VW-1 & CUL FT1 vertical flame test
Environmental requirements: RoHS & REACH;
APPLICATION
Internal Wiring of Class 2 Circuits in electronic equipment
PARAMETER
Conductor | Insulation | Maximun Resistance at 20℃ | ||||
导体 | 绝缘 | |||||
AWG | No./mm | Nom.Dia. | Nom.Thick. | Average | 20℃最大导体电阻Ω/km | |
线规 | 线数/线径 | 外径 | 平均厚度 | 参考外径 | ||
mm | mm | mm | ||||
4 | 420/0.254 | 6.47 | 0.12 | 8.00 | 0.882 | |
6 | 266/0.254 | 5.15 | 0.12 | 6.50 | 1.403 | |
8 | 168/0.254 | 4.10 | 0.12 | 5.30 | 2.23 | |
10 | 105/0.254 | 3.01 | 0.12 | 4.20 | 3.546 | |
12 | 65/0.254 | 2.37 | 0.12 | 3.50 | 5.64 |